TAKE PICTURES AUTOMATICALLY
Click here to view the SK-660A brochure
Click here to view the SK Series brochure
Click here to view the technical parameters pdf
Click here to view the SK-650AFundus Camera brochure 1
Click here to view the SK-650AFundus Camera brochure 2
Advantage of Non-mydriatic Fundus Camera
- Reduce the pain and inconvenience of the patient
- Save time for patients and doctors, dilating need about 20 minutes
- Won't Affect patients' activity which improving their compliance
- Non-mydriatic image with reliable quality
45° full-circle design
New optical design guarantees 45° full-circle image and avoid losing fundus information
Switching anterior-posterior para-position compensation lens
Using additional compensation mode of fundus para-position, cleverly solve the problem of para-position blind area from the ocular surface to fundus, which make the fundus para-position becomes easier
Split-line aligning focus
Using split-line aligning focus method which indicated focus status more objectively compared to the traditional one which can avoid turbid eye medium holding back the image focus.
Even under the black background such as FFA, split-line aligning system still helpful for clear images capturing.
Exposure intensity automatic controlled
The system identiy patients' retinal status and control exposure intensity automatically, which realize the best exposure condition. It assures to get perfect image every time.
Watch the Introduction + Operation video
SK-660A | SK-650B | ||
Optical lens | Aspherics system | ||
Test mode | Non-mydriatic fundus | Non-mydriatic and FFA | |
Min.Pupil Size | 3.3mm | ||
Fundus Observation | Switching Optical anterior-posterior compensation lens | Moved platform | |
Focus | Split-line aligning focusing | ||
Focus Mode | Auto / Manual | Manual | |
Capture | Auto / Manual | Manual | |
Digital Camera | CANON EOS Technology | ||
Color Image Resolution | 5184*3456 | ||
Monochrome Image resolution | / | 1360*1024 | |
Compensation range | -25D ~ +30D | ||
Fundus observation para-position indication |
Dots overlap | ||
Fixation targe | 9 internal fixation target | External eye fixation lamp & 9 internal fixation target |
|
Maximum angle of view | 45° | ||
Optical head tilting | / | / | Horizontal±30° Vertical±12.5° |
Working distance | 40mm ± 2mm | ||
software | Support Dicom 3.0, support hospital HIS/PACS system. Image processing, easily operate, strong analysis, support fundus Mosaic, image post processing, measurement, patient profile management |